ProductsEN 10263

MATERIAL DATA · COLD FORMING

10NiCr5-4 Cold-drawn steel wire

Technical data for 10NiCr5-4 cold-drawn steel wire, compliant with the EN 10263 standard. Review the current grade’s chemical composition, mechanical properties, and relevant technical specifications.

10NiCr5-4 Cold-drawn steel wire product image
10NiCr5-4 · Cold-drawn steel wire
01StandardEN 10263
02Grade10NiCr5-4
03Product formCold-drawn steel wire
04Delivery noteConfirmed by order specification

Material technical data

Only data directly related to this material is shown here. Inspection, equipment, process and packaging information is linked separately.

1. Combinations of delivery conditions

Table 1 – Combinations of delivery conditions, product forms, and conformity requirements

Table 2 – Surface quality under delivery conditions

Surface condition upon deliverySymbolBarRolled wireWire
unless otherwise agreedhot-rollednone or +ARX —X —
Special surface condition delivered by agreementcold-drawn+C— X— -X
after-drawn+LC— X— XX
peeled+PEXXX

2. Chemical composition

Table 3 – Steel grades and chemical composition. Cast analysis, mass fraction %

Steel gradeCSi max.ǎMnP maxSCrMoNiBCu max.
Abbreviated nameMaterial number
10NiCr5-4 12NiCr3-2 17CrNi6-61.5805 1.5701 1.59180.07 to 0.12 0.09 to 0.15 0.14 to 0.200,30 0,30 0,300.60 to 0.90 0.30 to 0.60 0.50 to 0.900,025 0,025 0,0250.025 max 0.025 max. 0.025 max0.90 to 1.20 0.40 to 0.70 1.40 to 1.701.20 to 1.50 0.50 to 0.80 1.40 to 1.700,25 0,25 0,25
a A lower silicon content or a specified silicon range may be agreed upon at the time of order. NOTE 1 Elements not listed in this table should not be intentionally added to the steel, except for final refining of the melt, without the buyer’s consent. All reasonable precautions shall be taken to prevent the introduction of such elements from scrap and other materials used in production that could adversely affect hardenability, mechanical properties, and service performance. NOTE 2 For steels with hardenability requirements (see Tables 8 and 9), smaller deviations from the specified limits are permissible (with the exception of sulfur and phosphorus), provided that they do not exceed the values given in Table 4 for carbon 0,01 %and for the other elements. NOTE 3 To improve the results of cold heading, it is possible to add 0,020 %to 0.050 %aluminum.

Table 4 – Permissible limit deviations for the applicable limits of workpiece analysis and melt analysis in Table 3

ElementsLimit values according to melt analysis, mass fraction in %Limits for product analysis, mass fraction in %a
C≤0,24±0.02
Si≤0,30±0,03
Mn≤1,00±0,04
>1,00 ≤1,40±0,06
P≤0,025+0,005
S≤0,040+0,005
Cr≤1,70±0,05
Mo≤0.30±0.0.3
>0.30 ≤0,50±0,04
Ni≤1,00±0,03
>1,00 ≤1,70±0,05
B≤0,005(±0,0003
Cu≤0.25+0.03
a ± means that, for a given melt, either the upper or the lower limit of the range specified for melt analysis in Table 3 may be exceeded, but not both simultaneously. b For steels with a defined sulfur range (0,020 %to 0,040 %according to melt analysis), the tolerance is ±0.005 %.

3. Mechanical properties

Table 7 – Mechanical properties of alloy steels

Steel gradeDiameterDelivery condition
Short nameWork material numberOver mmbis mm+AC+FP+U+C+AC+U+C+AC+LC+AC+C
Rmmax. MPaZamin. %Rmmax. MPaZ min. %Rmmax. MPaZ min. %Rmmax. MPaZ min. %Rmmax. MPaZ min. %
10NiCr5-41.5805255206456062
51052062137187500645406264059
104052062137187500645406263059

4. Hardenability requirements

Table 8 – Hardness limits for steel grades with normal hardenability requirements (H grade, see 6.4.1)

Table 9 – Hardness values for steel grades with narrow Greny hardenability requirements (HH and HL grades; see 6.4.2)

Steel gradeSymbolAustenite‑Transformation TemperatureYield StrengthHRC Hardness at a Distance from the Quenched End (mm)
Abbreviated nameMaterial number
C±5℃235791113152025303540
10NiCr5-41.5805+HH880max.413937343230
min.332926242120
min44434240383634322927262524
min41403936333028262321

Application and ordering note

Chemical composition, mechanical properties, tolerances and delivery condition must be confirmed against the applicable standard edition, customer drawing and order specification.

Send a technical enquiry

Contact technical team →
Technical enquiry